This article walks you through the process of upgrading from a prior version of ScanPath Server to a more current version.  If the ScanPath Connector component needs to be upgraded as well, please uninstall the current version before installing the updated version of the Connector.

Upgrade Preparations

Before upgrading, please make note of the following information:

...

  1. If you have custom workflow processes for ScanPath, you will need to export each process first.  To export:

    1. Browse to "C:\Program Files (x86)\Prism Software\ScanPath\Server" (default) and run the Administrator.exe file.Open the ScanPath Workflow Editor application (located in the "WorkFlow" section of the ScanPath Configuration Tool).
    2. Connect to the ScanPath Server by going to File > Connect.
    3. For each custom process, select the process in the Processes Pane then go to File > Export.
       
  2. Uninstall all applicable ScanPath components from the Programs and Features list of Windows:

    1. ScanPath
    2. ScanPath WebLinker
    3. ScanPath WebLinker Service
    4. ScanPath ScanToBarcode

  3. In the ScanPath Server installation directory ("C:\Program Files (x86)\Prism Software\ScanPath\Server" by default), delete the "DocSystemDB.vdb3" file.  (This is an old database file that will be automatically refreshed after the upgrade.)

  4. If applicable, right click on the properties of the downloaded ZIP file and unblock it, and then click "OK".

  5. Extract the entire ZIP file to a local folder and install each of the ScanPath components that were removed earlier in Step 2, following the instructions in the included installation guide.  Please be sure to provide the information you noted during the Upgrade Preparations section where appropriate.

  6. If applicable, import the custom processes from Step 1 using the ScanPath Administrator Workflow Editor application.

  7. Open the ScanPath Configuration Tool and go through each of the configuration settings.  Please note that the menu options have changed since the previous version and may require some reconfiguration.

  8. Please go into the Windows Services list and change the ScanPathSvc service properties to use the same "Log On" tab settings noted during the Upgrade Preparations section.

    Note: You will need to restart this service in order for the log on changes to take effect.